AIRSTAGE SINGLE-ROOM MINI-SPLIT SYSTEMS Features Explanation

Auto Louver: Up/Down

Auto Louver: Up/Down: Redirects airflow automatically with seven position up and down motion which can be set to auto swing.Auto Louver: Up/Down: Redirects airflow automatically with seven position up and down motion which can be set to auto swing.
Redirects airflow automatically with seven position up and down motion which can be set to auto swing.

Auto Louver: 4 Way

Auto Louver: Up/Down: Redirects airflow automatically with seven position up and down motion which can be set to auto swing.
Redirects airflow automatically with up/down and left/right motion.

Automatic air flow adjustment

Automatic air flow adjustment: The micro-computer automatically adjusts the air flow effectively to follow the changes of room temperature. Auto Louver: Up/Down: Redirects airflow automatically with seven position up and down motion which can be set to auto swing.
The micro-computer automatically adjusts the air flow effectively to follow the changes of room temperature.

Auto Changeover (heating to cooling or vice-versa)

Auto restart: In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored. Auto Louver: Up/Down: Redirects airflow automatically with seven position up and down motion which can be set to auto swing.
Automatically alternates between heating or cooling if the room temperature falls 4 ̊F below the set temperature when cooling or rises 4 ̊F above set temperature when heating.*

Minimum Heat Mode

Minimum Heat Mode: Sets room temperature to 50°F, keeping temperatures above freezing and reducing power consumption. Minimum Heat Mode: Sets room temperature to 50°F, keeping temperatures above freezing and reducing power consumption.
Sets room temperature to 50°F, keeping temperatures above freezing and reducing power consumption.

Powerful Operation

Powerful Operation: 20 minutes of continuous operation at maximum airflow and maximum compressor speed. Rapid cooling and heating makes the room comfortable quickly. Powerful Operation: 20 minutes of continuous operation at maximum airflow and maximum compressor speed. Rapid cooling and heating makes the room comfortable quickly.
20 minutes of continuous operation at maximum airflow and maximum compressor speed. Rapid cooling and heating makes the room comfortable quickly.

Economy Mode

Economy Mode: Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating. Economy Mode: Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating.
Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating.

Energy Saver

Energy Saver: Keeps room cool enough for comfort by using a relaxed thermostat setting reducing power consumption. Energy Saver: Keeps room cool enough for comfort by using a relaxed thermostat setting reducing power consumption.
Keeps room cool enough for comfort by using a relaxed thermostat setting reducing power consumption.

Auto Restart/Reset

Auto Restart/Reset: Following a power failure, systems will automatically restart in the same operating mode as before, once power has been restored. Auto Restart/Reset: Following a power failure, systems will automatically restart in the same operating mode as before, once power has been restored.
Following a power failure, systems will automatically restart in the same operating mode as before, once power has been restored.

ENERGY STAR® Qualified

Energy Saver: Keeps room cool enough for comfort by using a relaxed thermostat setting reducing power consumption. Energy Saver: Keeps room cool enough for comfort by using a relaxed thermostat setting reducing power consumption.
Qualified products and practices help you save money and reduce greenhouse gas emissions by meeting strict energy efficiency guidelines set by the U.S. Environmental Protection Agency and the U.S. Department of Energy.

Apple Catechin Filter (polyphenol ingredient from apples)

Apple Catechin Filter (polyphenol ingredient from apples): Dust, mold spores and microorganisms are absorbed onto the filter by static electricity and growth is inhibited and deactivated. 3 - 12 month life expectancy, depending on environment. Apple Catechin Filter (polyphenol ingredient from apples): Dust, mold spores and microorganisms are absorbed onto the filter by static electricity and growth is inhibited and deactivated. 3 - 12 month life expectancy, depending on environment.
Dust, mold spores and microorganisms are absorbed onto the filter by static electricity and growth is inhibited and deactivated. 3 - 12 month life expectancy, depending on environment.

Ion Deodorizing Filter

Ion Deodorizing Filter: Deodorizes by decomposing absorbed odors using the oxidizing and reducing effects of ions generated by fine ceramic particles. 3 year life expectancy. Wash to restore surface action. Ion Deodorizing Filter: Deodorizes by decomposing absorbed odors using the oxidizing and reducing effects of ions generated by fine ceramic particles. 3 year life expectancy. Wash to restore surface action.
Deodorizes by decomposing absorbed odors using the oxidizing and reducing effects of ions generated by fine ceramic particles. 3 year life expectancy. Wash to restore surface action.

Sleep Timer

Sleep Timer: Automatically adjusts the temperature while you sleep to make you more comfortable. Sleep Timer: Automatically adjusts the temperature while you sleep to make you more comfortable.
Automatically adjusts the temperature while you sleep to make you more comfortable.

Program timer

Program timer: This digital timer allows selection of one of four options:ON, OFF, ON → OFF or OFF → ON.
This digital timer allows selection of one of four options:ON, OFF, ON → OFF or OFF → ON.

24 Hour Timer

24 Hour Timer: Allows for one on/off cycle during a 24 hour period. 24 Hour Timer: Allows for one on/off cycle during a 24 hour period.
Allows for one on/off cycle during a 24 hour period.

Weekly Timer

Weekly Timer: Allows you to set on/off time twice a day and a different on/off time by day. Weekly Timer: Allows you to set on/off time twice a day and a different on/off time by day.
Allows you to set on/off time twice a day and a different on/off time by day.

Dry Mode

Dry Mode: Allows for moisture removal in low load conditions of up to 50% of rated moisture removal capacity. Dry Mode: Allows for moisture removal in low load conditions of up to 50% of rated moisture removal capacity.
Allows for moisture removal in low load conditions of up to 50% of rated moisture removal capacity.

Energy Saving Program (ESP)

Energy Saving Program (ESP): If a space is left without turning the unit off, ESP knows that it is unoccupied and 20 minutes later, temperature is adjusted accordingly until users return to the room. Function is disable in split-zone installations. Energy Saving Program (ESP): If a space is left without turning the unit off, ESP knows that it is unoccupied and 20 minutes later, temperature is adjusted accordingly until users return to the room. Function is disable in split-zone installations.
If a space is left without turning the unit off, ESP knows that it is unoccupied and 20 minutes later, temperature is adjusted accordingly until users return to the room. Function is disable in split-zone installations.

Quiet Mode (Indoor Unit)

Quiet Mode (Indoor Unit): An extra quiet fan speed to make sure you are not disturbed. Quiet Mode (Indoor Unit): An extra quiet fan speed to make sure you are not disturbed.
An extra quiet fan speed to make sure you are not disturbed.

Outdoor Unit Low Noise

Limits compressor and fan speed during high speed operation for a 3 dB noise reduction. Limits compressor and fan speed during high speed operation for a 3 dB noise reduction.
Limits compressor and fan speed during high speed operation for a 3 dB noise reduction.

Power Diffuser

Power Diffuser: An additional louver that opens based on monitoring sensors to quickly enhance immediate comfort needs.
An additional louver that opens based on monitoring sensors to quickly enhance immediate comfort needs.

Low Ambient Cooling

Low Ambient Cooling: Can operate in cooling mode even when outdoor ambient is 0°F, 14°F or 32°F, depending on model, without modification. Operation outside of factory specification is not recommended. Low Ambient Cooling: Can operate in cooling mode even when outdoor ambient is 0°F, 14°F or 32°F, depending on model, without modification. Operation outside of factory specification is not recommended. Low Ambient Cooling: Can operate in cooling mode even when outdoor ambient is 0°F, 14°F or 32°F, depending on model, without modification. Operation outside of factory specification is not recommended.
Can operate in cooling mode even when outdoor ambient is 0°F, 14°F or 32°F, depending on model, without modification. Operation outside of factory specification is not recommended.

Cold Prevention

Cold Prevention: Indoor coil will warm prior to fan operating, preventing cold air during heating mode. Cold Prevention: Indoor coil will warm prior to fan operating, preventing cold air during heating mode.
Indoor coil will warm prior to fan operating, preventing cold air during heating mode.

Slender Fit

Slender Fit: Cassette body can be moved downward into the room 1-3/8” to accommodate limited ceiling space. Slender Fit: Cassette body can be moved downward into the room 1-3/8” to accommodate limited ceiling space.
Cassette body can be moved downward into the room 1-3/8” to accommodate limited ceiling space.

Remote Temperature Sensor

Remote Temperature Sensor: Room temperature sensor is located in optional wired remote controller only. Remote Temperature Sensor: Room temperature sensor is located in optional wired remote controller only.
Room temperature sensor is located in optional wired remote controller only.

Pump Down Operation

Pump Down Operation: Collects all refrigerant in system back into the outdoor unit when the unit is to be moved or before servicing the refrigerant circuit. Pump Down Operation: Collects all refrigerant in system back into the outdoor unit when the unit is to be moved or before servicing the refrigerant circuit.
Collects all refrigerant in system back into the outdoor unit when the unit is to be moved or before servicing the refrigerant circuit.

Daisy Chain

Daisy Chain: Ability to connect up to 16 identical style indoor units to one wired remote. Daisy Chain: Ability to connect up to 16 identical style indoor units to one wired remote.
Ability to connect up to 16 identical style indoor units to one wired remote.

High Ceiling Mode

High Ceiling Mode: Temperature at the top of a high ceiling room may be warmer than the space occupied; this mode adjusts for this difference. High Ceiling Mode: Temperature at the top of a high ceiling room may be warmer than the space occupied; this mode adjusts for this difference.
Temperature at the top of a high ceiling room may be warmer than the space occupied; this mode adjusts for this difference.

Branch Duct Capable

Systems are capable of attaching field-supplied branch ducts providing up to 38% of the cooling up to 16 feet away.

Fresh Air Intake

Fresh Air Intake: Outside air can be introduced by attaching field supplied flexible duct to fresh air knockouts. Fresh Air Intake: Outside air can be introduced by attaching field supplied flexible duct to fresh air knockouts.
Outside air can be introduced by attaching field supplied flexible duct to fresh air knockouts.

Base Pan Heater

Base Pan Heater: Prevents condensate from freezing on the outdoor unit. Base Pan Heater: Prevents condensate from freezing on the outdoor unit.
Prevents condensate from freezing on the outdoor unit.

Third Party Device Control

Third Party Device Control: Turns system on or off using a normally closed circuit. Interface with third party devices such as home automation. Third Party Device Control: Turns system on or off using a normally closed circuit. Interface with third party devices such as home automation.
Turns system on or off using a normally closed circuit. Interface with third party devices such as home automation.

Blue Fin Heat Exchanger

Blue Fin Heat Exchanger: Blue fin treatment to the outdoor unit’s heat exchanger
improves corrosion resistance. Blue Fin Heat Exchanger: Blue fin treatment to the outdoor unit’s heat exchanger
improves corrosion resistance.
Blue fin treatment to the outdoor unit’s heat exchanger improves corrosion resistance.

Long Piping Length

Long Piping LengthLong Piping Length
Long piping lengths between equipment offers flexible outdoor unit location options.

Hydro Fin Coating

Hydro Fin Coating
Clear hydrophylic treatment added to the outdoor unit's heat exchanger improves corrosion resistance.

Built-in Condensate Pump

Built-in Condensate Pump
Integrated into the indoor unit.

Expanded Heating Performance

Expanded Heating Performance
Delivers 100% of rated heating capacity at +5°F(-15℃℃).
Welcome to the Fujitsu General Resource Center.
This area is loaded with valuable information such as rebates, case studies,
videos, news, press releases, an efficiency calculator and an easy way to locate your local Fujitsu General contractor.